Manifold bracket must be attached to the main frame with 1 bolt and
locknut. By-pass hose should be attached to return under the tank with
hose attached to pressure relief valve.
Breakaway booms should be attached to center boom section using
11/4 bolt with locknut at first hole. Slotted breakaway is attached
with 1 bolt, one washer and locknut. Breakaway should be loose enough
to allow boom to swing back when an object is encountered! Boom chains
should be attached to top corners of center section and center hole in
boom with 1 bolt and locknut. Boom should be level with ground when
boom chains are adjusted.
Boom hose and nozzles should be installed by removing cap and nut
from T or L, inserted into appropriate hole in boom, then reassembled.
Nut should be tight enough to hold in boom, but nozzle cap should only
be finger tight. All nozzle openings should be facing rear of sprayer.
Rubber boom straps should be used either to hold boom in transport
position or hooked in chain with enough tension to allow boom to float.
Boom chain would be loose if properly installed.
Pasture broadcast nozzle, boom and handgun hoses should be run under
the tank and be attached to appropriate hose barb on manifold.
Pump hose should be installed with hose running from strainer under
the tank to outlet marked in on pump. Hose from out goes to
manifold. Make sure hose length on pump is right distance from your
tractor with pump mounted on tractor PTO and lift arms or hitch attached
to your tractor. Chain on pump should go around tractor lift arm.
After all accessories are installed, partially fill tank with water
and check all hoses and fittings for leaks. You may need to tighten some
fittings or hose clamps. Straps should be tightened after filling tank.
Valve at bottom of tank outlet should be open when running pump.
Always make sure strainer is clean prior to running sprayer.
Run sprayer using water to familiarize yourself with the operation
on various accessories. Recheck for leaks.
Pressure of sprayer is adjusted at pressure relief valve by screwing
in for higher pressure, out for lower pressure.
Tank and spray system should be flushed with clear water after use.
Chemicals should not be left in tank and system for prolonged periods of
time to avoid residual effect. Add anti-freeze to pump when unit is
stored for prolonged periods especially during winter.
If you dont find the answers call REMCOR at (903) 532-6214.